WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-757a
Regency P33 Sunrise
Gas Fireplace
10/19/09
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODEL: P33S-NG4 Natural Gas
P
33S-LP4 Propane
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Gas Fireplace

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Page 2 - To the New Owner:

Regency P33 SunriseTM Gas Fireplace10INSTALLATIONINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. Th

Page 3 - Gas Fireplace 3

Regency P33 SunriseTM Gas Fireplace 11INSTALLATIONINSTALLATIONMANTEL CLEARANCESNote: Ensure the paint that is used on the mantel and the facing is &q

Page 4 - TABLE OF CONTENTS

Regency P33 SunriseTM Gas Fireplace12INSTALLATIONINSTALLATIONNote: When constructing the framed opening, please ensure there is access to install the

Page 5 - SAFETY LABEL

Regency P33 SunriseTM Gas Fireplace 13INSTALLATIONGHIIMJLKPQON10" (254mm)dia. Hole throughwall Vent.Opening for gasconnectionTop Header.Wood, dry

Page 6 - REQUIREMENTS

Regency P33 SunriseTM Gas Fireplace14INSTALLATIONINSTALLATIONBeforeAfterBendhereTop Standoff(flat shippingposition)Top Standoffafter bendingThe Top Fa

Page 7 - DIMENSIONS

Regency P33 SunriseTM Gas Fireplace 15INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSINSTALLATIONMinimum Clearance RequirementsCanada1USA2A Clearan

Page 8

Regency P33 SunriseTM Gas Fireplace16INSTALLATIONWherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Riser V

Page 9

Regency P33 SunriseTM Gas Fireplace 17INSTALLATIONINSTALLATIONPipe LengthVerticalTerminalStorm CollarFlashingCeiling FirestopAdj.Pipe Length11" -

Page 10 - Close to Ceiling

Regency P33 SunriseTM Gas Fireplace18INSTALLATIONINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amerivent Dir

Page 11 - INSTALLATION

Regency P33 SunriseTM Gas Fireplace 19INSTALLATIONINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amerivent Di

Page 12

Regency P33 SunriseTM Gas Fireplace2To the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The P33 Sunri

Page 13

Regency P33 SunriseTM Gas Fireplace20INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS Vertical Terminations(Propane & Natural Gas)The shaded area in th

Page 14

Regency P33 SunriseTM Gas Fireplace 21INSTALLATIONINSTALLATIONFlex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#948-3053

Page 15

Regency P33 SunriseTM Gas Fireplace22INSTALLATIONINSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothResidenti

Page 16

Regency P33 SunriseTM Gas Fireplace 23INSTALLATIONINSTALLATION162468101214200122061430” (762mm)MinimumHeightRequirement4810181816Vertical Height (Feet

Page 17

Regency P33 SunriseTM Gas Fireplace24INSTALLATIONINSTALLATIONHorizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Three (3) 90o ElbowsOne

Page 18

Regency P33 SunriseTM Gas Fireplace 25INSTALLATIONINSTALLATIONHorizontal Venting with Three (3) 90o ElbowsVertical Venting with Two (2) 90o ElbowsVert

Page 19

Regency P33 SunriseTM Gas Fireplace26INSTALLATIONINSTALLATIONVertical Venting with Three (3) 90o ElbowsVertical Venting with Three (3) 90o Elbows

Page 20

Regency P33 SunriseTM Gas Fireplace 27INSTALLATIONRiser VentTerminationMin. 6-1/4"*(159mm)Diagram 3UNIT INSTALLATION WITH HORIZONTAL TERMINATIOND

Page 21

Regency P33 SunriseTM Gas Fireplace28INSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance. The gas valve i

Page 22

Regency P33 SunriseTM Gas Fireplace 29INSTALLATIONINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping syste

Page 23

Regency P33 SunriseTM Gas Fireplace 3MANUFACTURED MOBILE HOME REQUIREMENTSINFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Regency® prod

Page 24

Regency P33 SunriseTM Gas Fireplace30INSTALLATIONCONVERSION KIT# 434 - 970 FROM NG TO LPFor P33 Sunrise™ Using SIT 820 NOVA Gas ValveTHIS CONVERSION M

Page 25

Regency P33 SunriseTM Gas Fireplace 31INSTALLATIONINSTALLATIONWARNING!Do not overtighten the screw. Recommended to gripthe wrench by the short side.9)

Page 26

Regency P33 SunriseTM Gas Fireplace32INSTALLATIONINSTALLATIONDC SPARK BOX REPLACEMENTDC SPARK BOX BATTERY REPLACEMENT1) Remove the faceplate by lifti

Page 27

Regency P33 SunriseTM Gas Fireplace 33INSTALLATIONWALL SWITCH1) Run the supplied wire through the right or left side gas inlet opening. Be careful n

Page 28 - Diagram 1

Regency P33 SunriseTM Gas Fireplace34INSTALLATIONWIRING DIAGRAM AERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to ei

Page 29

Regency P33 SunriseTM Gas Fireplace 35INSTALLATIONINSTALLATIONGT REMOTE WIRING DIAGRAMRed wireBlack wireGreen wireExtra wires not usedWhite wirespade

Page 30

Regency P33 SunriseTM Gas Fireplace36INSTALLATIONINSTALLING THE OPTIONAL FAN120 Volt AC power is needed for the fan switch and blower. The fan can be

Page 31

Regency P33 SunriseTM Gas Fireplace 37INSTALLATIONINSTALLATIONOPTIONAL REFLECTIVE PANEL INSTALLATION1) If already installed, remove the burner assem

Page 32

Regency P33 SunriseTM Gas Fireplace38INSTALLATIONGLASS CRYSTALINSTALLATION ON BURNEROPTIONAL PEBBLE INSTALLATION ON FIREBOX BASEINSTALLATIONSpread the

Page 33

Regency P33 SunriseTM Gas Fireplace 39INSTALLATIONINSTALLATIONSTANDARD FLUSH DOOR INSTALLATIONThe standard fl ush door comes with a black frame. To ins

Page 34

Regency P33 SunriseTM Gas Fireplace4TABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...5REQUIREMEN

Page 35

Regency P33 SunriseTM Gas Fireplace40INSTALLATIONFACEPLATE INSTALLATIONINSTALLATION1) Install the control shield with 2 #8 - 1/2" Phillips screw

Page 36

Regency P33 SunriseTM Gas Fireplace 41INSTALLATIONINSTALLATIONDiagram 7Diagram 8Diagram 9FaceplateFaceplate Support6) Hook the fl ange on the facepla

Page 37

Regency P33 SunriseTM Gas Fireplace42OPERATIONOPERATING INSTRUCTIONS1) Read and understand these instructions before operating this appliance.2) Che

Page 38

Regency P33 SunriseTM Gas Fireplace 43OPERATIONOPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONSTO TURN OFF GAS APPLIANCEFOR YOUR SAFETY READ

Page 39

Regency P33 SunriseTM Gas Fireplace44MAINTENANCEMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For relighting,

Page 40

Regency P33 SunriseTM Gas Fireplace 45MAINTENANCEVALVE TRAY REPLACEMENTMAINTENANCEREMOVING VALVE1) Shut off the gas supply.2) Remove the faceplate.3

Page 41

Regency P33 SunriseTM Gas Fireplace46PARTS LISTPARTS LISTMAIN ASSEMBLY Part # Description 434-907 Refl ective P

Page 42 - OPERATING INSTRUCTIONS

Regency P33 SunriseTM Gas Fireplace 47WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our inter

Page 43

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 44 - MAINTENANCE

Regency P33 SunriseTM Gas Fireplace 5INSTALLATIONSAFETY LABELThis is a copy of the label that accompanies each P33 Sunrise™ Direct Vent Gas Fireplace.

Page 45

Regency P33 SunriseTM Gas Fireplace6INSTALLATIONREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additi

Page 46 - PARTS LIST

Regency P33 SunriseTM Gas Fireplace 7INSTALLATIONDIMENSIONSUNIT DIMENSIONS

Page 47 - WARRANTY

Regency P33 SunriseTM Gas Fireplace8INSTALLATION11) Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servi

Page 48

Regency P33 SunriseTM Gas Fireplace 9INSTALLATIONINSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate noted on