FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-262a
MODELS: P33-NG3 Natural Gas P33-LP3 Propane
P33-3 Zero Clearance
Direct Vent Gas Fireplace
01/04/06
Owners &
Installation Manual
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency-fi re.com
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Installation Manual

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-262aMODELS: P33-NG3 Natural Gas P33-LP3 PropaneP33

Page 2

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceEXTERIOR VENT TERMINATION LOCATIONSINSTALLATION.BBBBACVVVVVVVAAVFixedFixedOpenableClosedClosedOp

Page 3 - TABLE OF CONTENTS

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceWherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Ri

Page 4 - SAFETY LABEL

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceTermination CapWall Thimble 2 pieces(10" (254mm) Outer Diameter)2”x4”or2”x6”(21mm x 102mmor

Page 5

Regency P33-3 Zero Clearance Direct Vent Gas FireplacePipe LengthVerticalTerminalStorm CollarFlashingCeiling Firestop24" (610mm)Pipe LengthAdj.Pi

Page 6

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRIGID PIPE VENTING COMPONENTS LISTAll Simpson Dura-Vent components are available dir

Page 7

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor level

Page 8

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceThe P33-3 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for P

Page 9

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSREGENCY DIRECT VENT SYSTEM (FLEX)(Prop

Page 10 - INSTALLATION

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceHorizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Two (2) 90o ElbowsHorizontal V

Page 11

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceHorizontal Venting with Three (3) 90o ElbowsVertical Venting with Two (2) 90o Elbows Option V

Page 12

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Stove by FPI FIRE

Page 13

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVertical Venting with Three (3) 90o ElbowsVertical Venting with Three (3) 90o Elbows

Page 14

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceFlex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#948-30535 ft (11

Page 15

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceVenting Arrangements - Vertical Terminations with Co-linear Flex System for bothResidential &

Page 16

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDiagram 3HORIZONTAL INSTALLATIONSDiagram 1 b) Horizontal runs of vent must be sup-p

Page 17

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance

Page 18

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by clo

Page 19

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONConversion Kit from Natural Gas to Propane Model #431-969 for P33-3 using SIT 820 NO

Page 20

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONNote: The logs must not be in the unit.3) Insert the back brick panel by carefully

Page 21

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceDiagram 1Diagram 3STANDARD FLUSH DOORThe standard fl ush door comes with a black frame. To instal

Page 22

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceOPTIONAL BAY DOORThe Bay louvers MUST be usedwith the Bay glass option.The optional Bay door is

Page 23

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceTABLE OF CONTENTSLouvers - Flush ... 29Dou

Page 24

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi r

Page 25

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceFULL SCREEN FRONTINSTALLATION1) Before beginning the installation, remove the Glass Door from

Page 26

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATION6) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bottom

Page 27

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceOPTIONALWALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as per

Page 28

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONCaution: Ensure that the wires do not touch any hot surfaces and are away from sharp

Page 29

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONINSTALLING THE OPTIONAL FAN120 Volt AC power is needed for the fan switch and blower

Page 30

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceOPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS

Page 31

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceAERATION ADJUSTMENTThe air shutter can be adjusted by moving the adjusting wire up or down. The

Page 32

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For religh

Page 33

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceMAINTENANCE THERMOPILE/THERMOCOUPLE1) Open the bottom louvers.2) Loosen the thermocouple or th

Page 34

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceThis is a copy of the label that accompanies each P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 35

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace10) Undo the pilot tube from the valve with a 7/16" wrench.REMOVING VALVE1) Shut off the

Page 36 - OPERATING INSTRUCTIONS

Regency P33-3 Zero Clearance Direct Vent Gas FireplacePARTS LISTMain Assembly Part # Description Part # Description

Page 37

Regency P33-3 Zero Clearance Direct Vent Gas FireplacePARTS LIST

Page 38 - MAINTENANCE

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceBurner & Log Assembly Part Description 53) 430-055 Gaske

Page 39

Regency P33-3 Zero Clearance Direct Vent Gas FireplacePARTS LISTFlush Front & Louvers Part # Description Part #

Page 40

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace 430-930 Bay Front Complete106) 940-079/P Side Glass107) 936-243 Glass Gasket108) 940-078/P

Page 41 - PARTS LIST

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace________________________________________________________________________________________________

Page 42

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceWARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addi

Page 43

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 44

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONIMPORTANT: SAVE THESE INSTRUCTIONSThe P33-NG3 or P33-LP3 Direct Vent Fireplace must

Page 45

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceINSTALLATION CHECKLIST1) Locate appliance a) Room location, page 6 b) Clearances to Combust

Page 46

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceCOMBUSTIBLE MANTELSINSTALLATIONClearances for Bay or Flush FrontBecause of the extreme heat this

Page 47 - WARRANTY

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace16-1/2”(419mm)Minimum4"(102mm)3"(76mm)1-1/2"(38mm)30”(762mm)10" (254mm)dia.

Page 48

Regency P33-3 Zero Clearance Direct Vent Gas FireplaceThe Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly po-sit