30
OPERATING INSTRUCTIONS
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
FIRST FIRE
The FIRST FIRE in your heater is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
rst time you use it with the fan on.
When fi rst operated, the unit will release an
odour caused by the curing of the paint and
the burning off of any oils remaining from
manufacturing. Smoke detectors in the house
may go off at this time. Open a few windows to
ventilate the room for a couple of hours. The
glass may require cleaning.
NOTE: The main burner will always start on
"HIGH" and resume it's last setting after
20 seconds of operation.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
LIGHTING
INSTRUCTIONS
1) Plug the power cord into a power outlet.
2) Press and release the ON/OFF button once
to start the unit.
3) After approximately 3 seconds the spark
ignition system will spark for 40 seconds to
light the main burner.
4) If the main burner does not light, reset the
unit.
RESETTING
THE UNIT
1) Open the bottom louvre of the unit.
2) Press and release the reset button, located
on the unit's control panel once.
3) Wait for approximately 3 seconds and the
pilot sparks can be heard and seen. It would
take 2 to 3 seconds for the fl ame to be lit.
NOTE: A period of 30 seconds must pass before
another reset is attempted.
SHUTDOWN
INSTRUCTIONS
1) Press the ON/OFF button once.
2) Turn off all electric power to the appliance if
service is to be performed.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all flueing and the cap is
unobstructed.
6) Verify log placement.
REMOTE CONTROL
Use the Regency
®
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter and a wall mounting plate.
1) Choose a convenient location to mount
the hand held transmitter, protection from
extreme heat is very important.
The remote can also be used as a wall
thermostat.