Regency Fireplace Products B36XTCE Installation Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Regency B36XTCE Gas Fireplace
5
SAFETY LABEL
This is a copy of the label that accompanies
each Bellavista™ B36XTCE Direct Vent Gas
Fireplace. We have printed a copy of the
contents here for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
410
410
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
919-153
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Listed:
Certified for/Certifi e pour:
Tested to:
VENTED GAS FIREPLACE HEATER /
CANADA and U.S.A.
FOYER AU GAZ À ÉVACUATION
é
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2009/CSA 2.33-2009
Electrical supply/Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
0" Clearance to
combustibles from:
Mantel Clearances from
Fireplace Opening:
Side Wall Clearance
from Fireplace Opening
Ceiling from Top of
Fireplace Opening:
Mantel Depth:
Alcove Clearances:
Sides, bottom and rear of unit
(A) Min. 15-1/2" (394mm)
B) Min. 12” (305mm)
C) 39” (991mm)
D) Max. 12” (304mm)
F) Max. Depth 36" (914mm)
*Top - 3-1/2" (89mm) non-combustible
material required above unit.
(on one side)
E) Min. Width 84" (2134mm),
(See Instruction Manual for
detailed instructions)
ÉÉ
é
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le B36XTCE-LP
PROPANE GAS: Model B36XTCE-LP
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
NATURAL GAS: Model B36XTCE-NG
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le B36XTCE-NG
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
l'altitude
Calorifique
Calorifique
é
ééé
é
é
é
5.0" (1.25 kPa)
3.5" (0.87 kPa)
1.6" (0.40 kPa)
#35 DMS
0-4500 ft/pi (0-1372 m)
WC/C.E.
WC/C.E.
WC/C.E.
21,500 Btu/h (6.3 kW)
31,000 Btu/h (9.09 kW)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
l'altitude
Calorifique
Calorifique
ééé
é
é
é
11" (2.74 kPa)
10" (2..49 kPa)
6.4" (1.60 kPa)
#51 DMS
0-4500 ft/pi (0-1372 m)
WC/C.E.
WC/C.E.
WC/C.E.
25,000 Btu/h (7.33 kW)
31,000 Btu/h (9.09 kW)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCSA225.1/NFPA501A, Manufactured Home Installations Standard orANSIA119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #576-972).
Fan Part # 576-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installationANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
POUR UTILISATION UNIQUEMENTAVECLES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
4001172
C
Floor
Wall
Ceiling
A
F
E
D
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 71 72

Comments to this Manuals

No comments